QUALITY CONTROL ASSURANCE FOR RADIOPHARMACEUTICALS ON THE PHARMACEUTICAL MARKET OF UKRAINE
Abstract
The article substantiates the proposal to optimize the quality control of radiopharmaceuticals using a domestic radionuclide calibrator for nuclear medicine, with the help of which it is possible to determine the radionuclide purity and measure the total radioactivity produced by a series of radiopharmaceuticals.
The purpose of the work is to optimize the process of quality control of FDG, taking into account the half-life of 109 minutes, which in turn reduces the time of quality control and reduces the cost of the dose of FDH.
The subject of the study, Ftorodezoxiglucose 18F, a solution for injection, which is most often, about 90% compared with other radiopharmaceuticals, is used in nuclear medicine for PET research on cancer.
Conclusions. Using the radionuclide calibrator for nuclear medicine, the results of FDH quality control were obtained: the gamma radiation spectrum corresponds to 511 keV energy of all studied series. The total radioactivity of the sample series: 20181228/184 was 106 MBq, the sample series: 20181228/185 was 135 MBq and the sample series: 20181229/186 was 190 MBq.
References
Семенів І.П., Кметюк Я.В., Москалець О.І. Досвід впровадження та перші підсумки застосування позитронно-емісійної томографії у Всеукраїнському центрі радіохірургії. Променева діагностика. Променева терапія.2013. №2-3. С. 88-92.
Наказ Міністерства охорони здоров’я України від 05.10.2010 р. № 836 «Методичні рекомендації до діагностичного матеріалу Фтордезоксиглюкоза [18 F] (FLUDEOXYGLUCOSE [18 F])».
Радіонуклідний калібратор для ядерної медицини: пат. 60782 Україна: МПК (2011.01), G01T 1/00; заявл. 25.06.2011.
Спосіб промислового виробництва екстракційного технецію 99М: пат. 86967_2 Україна; заявл. 10.01.2014.